Toll Free: 888.973.0079

Pigging Solutions for Today's Pipeline Applications

Pig Pro Technical Data

Electrical

LSX Limit Switch - weather sealed, explosion proof enclosures meet NEMA standards: 1, 3, 4, 6, 9 and 13. UL listed and CSA certified: Class I, Div.1, Groups B,C and D. Class II, Div.1, Groups E, F and G.

Electrical Ratings

10 amps continuous carry. Circuits on any pole must be the same polarity.

AC Volts Pilot Duty : 600VAC, 720VA
Electrical Rating Circuitry VAC Amps at 0.35 Power Factor
Make Break
B Double Pole Double Throw 120 30 3
240 15 1.5
480 7.5 0.75
600 6 0.60
 
DC Volts Pilot Duty : 240VDC, 30 watts
Electrical Rating Circuitry VDC Make and Break Amps
Inductive Resistive
B Double Pole Double Throw 120 0.25 0.80
240 0.15 0.40

Material

Description Material
Internal Parts 316Stainless Steel
Upper Housing Polyester Coated Aluminum
Fasteners 18-8Stainless Steel
Indicator Flag 90Durometer Polyurethane
Mounting Base ASTM A-10S Carbon Steel
Seals Fluorocarbon
Springs 302Stainless Steel
Thread Coating Impreglon

Operating

Temperature Range : -40°F to +
    -40°C to +90°C
Adjustable Penetration : 3/4"
    1.91 cm
Maximum Reset Pressure : 3,000 PSI
    21,000 KPA